SCXI-1303 Terminal Block The National Instruments SCXI-1303 terminal block provides a convenient method for connecting and disconnect signals to your system. National Instruments SCXI-1000 SCXI Chassis. com Description Technical Specifications FAQ Manuals & PDFs Drivers & Software National Instruments SCXI-1600 Data Acquisition. To set up and use your SCXI-1326 terminal block kit, you need the following components: SCXI-1326 High-Voltage Terminal Block Installation Guide SCXI-1326 high-voltage terminal block SCXI chassis SCXI-1162, SCXI-1163, SCXI-1162HV, or SCXI-1163R module Number 1 and 2 Phillips-head screwdrivers 1/10 in. The SCXI-1313 terminal block is shielded and has screw terminals that provide input connections for the SCXI-1125. SCXI-1303. So, neither of those components will be useful for output operations. Buyer pays for return shipping. My signal is current 4-20 mA; I connected a resistor of 0. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. 5 to Labview 8. The SCXI-1129 by National Instruments is In Stock & Ready to Ship. You can shorten this. The NI SCXI-1303 also has pullup and bias resistors that saturate the channel by applying +5 V at the open channel’s input. from the SCXI-1300, SCXI-1303, TBX-1303, and TC-2095 terminal blocks. Page 2 Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 For further support information, refer to the Technical Support Information document. SCXI Terminal Blocks 3 BUY ONLINE at ni. Installing the TBX-1303 Perform the following steps to mount the SH96-96 cable assembly and connect the TBX-1303 to the SCXI module. Order international: +1 609. Free Ground Shipping. - 3 x thermocouples. TBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-96 Open TC detection Isothermal construction, selectable ground referencing. Part Number: 186336B-01, 777966-40. Instruments from Silicon Valley Test & Measurement at used-line. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. com 8-Channel Strain/Bridge Input Module for SCXI —The SCXI‑1520 is a strain/bridge input module. Member Author 07-29-2010 07:16 PM. com DAQmx USB was unexpectedly terminated while. 5500. and 1/4 in. National Instruments SCXI-1102B Voltage Input Module. com todayTBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-96 Open TC detection Isothermal construction, selectable ground referencing. 9393. SCXI USB modules, such as the SCXI-1600, cannot be used in a PXI/SCXI combination chassis or in multichassis systems. 5mV; however using the new version of labview and DAQmx the thermocouples are reading 5V. com 327 SCXITerminal Blocks Data Acquisition andTBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-96 Open TC detection Isothermal construction, selectable ground referencing. • Input Signal: Up to 250 V. at used-line. SCXI-1303. Expand the chassis where the SCXI-1600 module is located. In Stock. National Instruments recommends that you replace the factory installed 10 MΩ bias resistor networks of the SCXI-1303 with the 10Ω resistors supplied with the kit. SCXI-1303 SCXI-1302 SCXI-1300 SCXI-1180 SCXI-1162HV SCXI-1160 SCXI-1141 SCXI-1126 SCXI-1125 SCXI-1124 SCXI. All prices are shown in USD. Any help would be appreciated. 2 and now my SCXI 1001 with a SCXI 1102 and SCXI 1303 terminal block no longer reads the correct voltage. 31We also know that the 1102 module is working properly since the SCXI-1303 is working with it. SCXI-1305 Terminal Block Figure 1. 51 or later Flathead screwdriver Number 1. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100National Instruments SCXI-1102B 32-Channel Thermocouple Amplifier Module. SCXI-1301. Fast Shipping. NI DAQ driver software is installed to operate the SCXI-1303 on. Each input channel includes an instrumentation amplifier and a 2 Hz. What You Need to Get Started To set up and use the SCXI-1305 terminal block, you need the following:. How Often Should You Verify? The measurement accuracy requirements of your application determine how often you should verify the performance of your SCXI-1303 terminal block. 884. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. This results in saturation to the positive rail. I have a SCXI 1303 front end module connected to a SCXI-1102 . Work with. Support Worldwide Technical Support and Product Information ni. 2. com 327 SCXITerminal Blocks Data Acquisition andThe CompactDAQ controller is a rugged, reliable, high-performance integrated controller with industry-standard certifications. Qty. Find many great new & used options and get the best deals for NATIONAL INSTRUMENTS MODEL SCXI-1303 TERMINAL BLOCK (PH23) at the best online prices at eBay! Free delivery for many products!SCXI-1200 PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, PLC MODULE, 12-BIT DATA ACQUISITON AND CONTROL MODULE, 12-BIT DACS, 16-BIT COUNTER/TIMER, 8 ANALOG INPUT CHANNELS, 24 LINES OF. SCXI-1303 Semiconductors from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY. Part Number: 185164A-01, 777687-03 scxi-1102 模块. There are eight pairs of s. However, the thermocouples (installed with mould) seem to record constant readings while the machine is molding samples, which should record 50 to 100 degree. 5 °C), the terminal block temperature sensor is •. The SCXI-1303 is an Isothermal Terminal Block developed by National Instruments. 2. are not included with this equipment unless listed in the above stock item description. 5 kHz or 22. The. Email: info@artisantg. Quick Quotes. For larger systems, or future expansion, you can also daisy chain up to eight SCXI‑1001 chassis with a single multifunction I/O device or. Manufacturer: National Instruments. The NI SCXI-1322 has an onboard sensor for cold junction compensation and can be utilized for many types of measurement. I have a SCXI 1303 front end module connected to a SCXI-1102 . Find many great new & used options and get the best deals for National Instruments Ni Scxi-1001 Chassis 12 Slot SCXI Mainframe With 11 Cards at the best online prices at eBay! Free shipping for many products!. I don't understand how I use this in Labview to gather the data. are available for purchase and repairs by Apex Waves. There are switches in the NI SCXI-1327 which allow or disallow the extended input voltage range separately for each channel. This document explains how to install and configure SCXI signal conditioning modules in SCXI-1000, SCXI-1001, SCXI-1000DC, or PXI/SCXI combination chassis, confirm the. I was wondering if you can do current signal processing with a twisted pair connection with the SCXI 1303 terminal/SCXI 1102 module. Phone: (217) 352-9330. 1553. Free Ground Shipping. BackNational Instruments SCXI-1313 High-Voltage Attenuator Terminal Block. For technical support outside the Americas, please contact your local National Instruments office. 5500. For technical support outside the Americas, please contact your local National Instruments office. However,. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. com ¥ ni. Instead of replacing the 10 ohm bias. But when I set CJC as "constant" (with. Phone: (217) 352-9330. Question: When utilizing a DMM to control a SCXI chassis, which mode can the DMM. The NI SCXI-1102B has Free Ground Shipping and a 1-3 Year Warranty. . The National Instruments SCXI-1503 16-Channel RTD Module provides 16 differential input channels, 16 channels of 100 μA current excitation, and one cold-junction (CJ) sensor channel. National Instruments recommends you verify your terminal block at least once every year. Right-click the chassis containing the SCXI-1600, and select Test to ensure that the SCXI-1600 is working properly. The National Instruments SCXI-1305 includes convenient BNC connectors for use with the SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126, SCXI-1140, SCXI-1141, SCXI-1142 and SCXI-1143 modules. National Instruments SCXI-1001 SCXI Chassis. Part Number: 182363D-01, 185136B-01, 185136A-01. I thought for sure I was trying to order. • Seller refurbished condition. National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThis unit is sealed in the manufacturer's bag. Fax: (240) 376-1381. See details for delivery est. National Instruments SCXI-1540 8-Channel LVDT Input Module. Trusted Supplier for Industrial & Military. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. USD ($) USD - United States. SCXI-1303 National Instruments, NI, SCXI-1303 National Instruments Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. Diversified models and products, and all kinds of rare and discontinued. ni scxi-1600 scxi-1300 scxi-1303 scxi-1000 机架 端子 NI SCXI-1349库存现货 Company advantage service: 1. SCXI Terminal Blocks National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ [email protected] kohm to have a voltage signal as insput of my module. Has been engaged in industrial control industry for a long time, with a large number of inventories. The function of the SCXI-1303 is to minimise errors caused by thermogradients whereas the function of the SCXI-1300 is for cold junction compensation. nasu wrote: I get noise from -4 to 10mAs. Sign up today to enjoy Radwell price on new product, surplus, and repairs. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100National Instruments PXI-1050 PXI Chassis. Page 7 Jumper W1. The function of the SCXI-1303 is to minimise errors caused by thermogradients whereas the function of the SCXI-1300 is for cold junction compensation. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. You can configure the module settings on a per channel basis for maximum flexibility in test cell applications measuring strain, force, torque, or pressure sensors. 5 to Labview 8. 11-12-2009 07:07 AM. Headquartered in Austin, Texas, it is a producer of automated test equipment and virtual instrumentation software. sensor to National Instruments for repair or replacement. Fax: (240) 376-1381. 4. We are best NI SCXI-1303 Cable adapter suppliers,we supply best NI SCXI-1303 for sale. We use SCXI 1320 to get measurements for voltages and SCXI1303 to get measurements for temperatures. Several new 1102/1303 pairs were recently added to increase the channel count. 5 °C), the performance of 4‑Slot, AC Chassis for SCXI —The SCXI‑1000 is a rugged, low‑noise chassis that powers SCXI modules as well as handles all timing, trigger, and signal routing between other modules and SCXI modules. Order international: +1 609. From SCXI 1303, we are using 88 channels (40. Engineers use NI PXI to build high-performance, mixed-measurement systems for validation and. SCXI-1303 Front Connector Pin Assignments SCXI-1303 Terminal Block Calibration Procedure ni. Academic and Research. 2. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. • Width: 1 5/8". This National Instruments SCXI-1327 High Voltage Attenuator Terminal Block is new from surplus stock. It is configured for 100/120/220/240 VAC power. SCXI-1303. SCXI-1303 SCXI-1302 SCXI-1300 SCXI-1180 SCXI-1162HV SCXI-1160 SCXI-1141 SCXI-1126 SCXI-1125 SCXI-1124 SCXI. National Instruments recommends you use the following instruments for verifying the performance of your SCXI-1303 terminal block: Calibrator—Fluke 5700A DMM—NI 4060. The inputs on this module can be multiplexed to one. com SCXI Terminal Blocks DAQ and Signal Conditioning SCXI Terminal Blocks. TBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-96 Open TC detection Isothermal construction, selectable ground referencing. 00 Current Offer-Page 1 National Instruments TBX-1303 Manual Get Pricing & Availability at ApexWaves. 500 MHz, 32-Channel RF Multiplexer Switch Module for SCXI —The SCXI‑1193 is a high-density RF relay module. Email: SCXI-1300 National Instruments SCXI-1300 SCXI Terminal Block from National Instruments | Buy Today from Artisan. Connect the DAQ device to a different computer or PXI controller slot, module or USB port. 5. 288. Ask for a quote on a Used National Instruments SCXI-1303 Misc. I'm attempting to measure the temperature in a k type thermocouple connected to a SCXI 1100 via an SCXI 1303. Trusted Supplier for Industrial & Military. The NI SCXI-1303 comes with part number 777687-03. Re: Lots of NI Hardware for Sale, New and Used - something for everyone! 01-10-2008 01:46 PM. For example, if you are working with NI-DAQmx 17, open the. It dissipates power at 7 W per slot, has a recommended operating temperature range of 0 to 50 °C, and a storage temperature range of –20 to 70 °C. This 4-Slot model offers low noise performance. com. . Phone: (217) 352-9330. I figured it would be a discrete input but am not sure how it would be read in LabVIEW. Part Number: 185136A-01, 777687-27. Fast Quotes & Shipping. are not included with this equipment unless listed in the above stock item description. Applications Engineer National Instruments . Refer to Figures 1 and 2 as needed. maximum signal ratings on the SCXI device can create a shock or fire hazard, or can damage any or all of the boards connected to the SCXI chassis, the host computer, and the SCXI device. Phone: (217) 352-9330. Experienced Expert Engineers that specialize in your application. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. All prices are shown in USD. . arincThe National Instruments SCXI-1102B/C,NI SCXI-1104/C,and the SCXI-1100 are an assortment of 32-channel analog input modules. Computer Four small screws (included in this kit) Two cable tie wraps SCXI-1353 Shielded Cable Installation Guide. National Instruments SCXI-1317 Front-Mounting Terminal Block for SCXI-1521 / SCXI-1521B Quarter-Bridge Strain Gage Module. This module can obtain millivolt, volt, 0 to 20 mA, and 4 to 0 mA current input signals. If that doesn't help, it could be that you don't have the correct cable or between the TBX-1303 and the SCXI-1102, or. Those hardly working channels start to work properly. 00. 04-24-2009 02:24 AM. 2. 308 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni. The lowest-priced item that has been used or worn previously. The outcome is saturation to the positive rail. The SCXI. com ¥ ni. The metallic adapter of this cable is designed to be fastened to the front panel connector of various SCXI modules, including the SCXI-1100, SCXI-1181, SCXI-1102, etc. Data Acquisition Basics Manual LabVIEW Data Acquisition Basics Manual January 2000 Edition Part Number 320997E-01. a quote and receive a price in about 15 minutes. Page 6 A3 (Temp Sensor) A2 (GND) A1 (+5 VDC) Figure 1. Returns: 30 days returns. TBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-96 Open TC detection Isothermal construction, selectable ground referencing. No. Before the user sets up their SCXI system, these items are required: an SCXI Chassis (SCXI-2000, SCXI-1000, SCXI-1000DC, or SCXI. SCXI-1102 module with a SCXI-1303 terminal block connected to it. com. Use them to build measurement and automation systems. Email: National Instruments SCXI-1302 SCXI Terminal Block | Easy Click-Quote-Buy Today! Fast Shipping. SCXI-1581 module with a SCXI-1300 terminal block connected to it. This model does not only supply power to SCXI modules, but also controls all trigger, timing, and signal routing functions as well. Data Acq. I also changed out the. Re: scxi 1308 noise. The faulty one is SCXI 1300. Note National Instruments does not recommend setting jumper W1 on the SCXI-1100 in the non-parking position. Any help would be appreciated. This module also has a cold-junction compensation sensor for temperature measurements. All prices are shown in USD. Related Manuals for National Instruments SCXI-1102. It also describes the NI-DAQmx software relative. National Instruments recommends that you replace the factory installed 10 MΩ bias resistor networks of the SCXI-1303 with the 10Ω resistors supplied with the kit. National Instruments Senior Applications Engineer National Instruments PXI-8421/8 8-Port RS485 Interface Card $ 109. All prices are shown in USD. CALIBRATION PROCEDURE SCXI -1303 TERMINAL BLOCK Introduction This document contains information and step-by-step instructions for verifying the performance of the. Find many great new & used options and get the best deals for Ni National Instruments SCXI-1303 Bloque Terminal Para Scxi Módulos 1100 1102 at the best online prices at eBay! Free shipping for many products!arinc & 1553 . Control Unit National Instruments SCXI SCXI-1102 User Manual (85 pages) I/O Systems National Instruments SCXI-1102 Calibration Procedure. Rated 4. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. To check the compatibility between the driver version and the LabVIEW version, see the Compatibility Table. If you need a specific configuration please contact Artisan Sales. Configuration: Bridge Completion: 350 Part Numbers: 190939B-01, 777966-21. SCXI Terminal Blocks National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Part Number: 182675-01. The NI SCXI-1102 module can obtain signals from RTDs as well when the SCXI-1581 delivers excitation. Order toll free: 800. Then, follow the steps below: 1. This. 09-03-2009 03:06 PM. Functionally equivalent to the SCXI-1304 terminal block, the SCXI-1305 includes switchable AC coupling circuitry and ground referencing on each channel. Next to the SCXI-1600 I also have: 1. SCXI Terminal Blocks National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. The SCXI-1303 consists of 32 channels. In the Americas, phone support is available on non-holiday weekdays from 7:00 a. are not included with this equipment unless listed in the above stock item description. to 7:00 p. I had previously tested the 1102 with a scxi 1303 I borrowed from another dept. Quick Quotes. It is a test and measurement platform that combines a controller with measurement instruments in a multi-slot chassis. . Find many great new & used options and get the best deals for NI National Instruments SCXI-1303 Terminal Block for SCXI Modules, at the best online prices at. Industry leading, price advantage, quality assurance 3. The SCXI-1102C by National Instruments is In Stock & Ready to Ship. 00 Add to cart; National Instruments SCXI-1303 32-channel isothermal terminal block $ 26. com. All prices. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。 system, National Instruments provides no-cost standard technical support via e-mail and phone for all registered users on all products. National Instruments NI SCXI 1000 1303 1302 1325 1161 1124. . high-accuracy thermocouple measurements, the SCXI-1303 includes isothermal construction that minimizes errors caused by thermal gradients between terminals and the cold-junction sensor. Part Numbers: 184826A-01, 184826B-01, 184826C-01, 184826D-01, 184826E-01, 184826F-01, 777570-01. Fast Quotes & Shipping. Click the Chassis tab. 5NRT1L:Find great deals on eBay for scxi 1124. at used-line. Order international: +1 609. All of the modules and terminal blocks will use this string with the exception of the SCXI 1112. 288. National Instruments recommends you verify your terminal block at least once every year. The National Instruments SCXI-1104C (Part Number: 776572-04C, 183087H-05) Voltage Input Module has 32 differential channels and is created for the signal conditioning of higher voltage signals. SCXI-MS100 Temperature Measurement System 2 SCXI-1000 chassis with AC power cord SCXI-1102 module SCXI-1303 terminal block SCXI-1349 cable assembly (cable and cable adapter) Phone: (217) 352-9330. Brand: National Instruments | Category: | Size: 0. The SCXI-1102B (Part Number: 776572-02B) has a three-pole lowpass filter with a 200 Hz cutoff frequency, 32 differential channels, and DC input coupling. The National Instruments SCXI-1346 is perfect for multichassis systems. We offer repair services with a 1 week turnaround and calibration services with a 2 week turnaround. Support Worldwide Technical Support and Product Information ni. are not included with this equipment unless listed in the above stock item description. Fax: (240) 376-1381. price advantage, quality assurance 3. National Instruments SCXI-1160 16-Channel General-Purpose Relay Module. Options. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Using the old version of labview thermocouple measurements are correct at 0. All prices are shown in USD. The NI SCXI 1001 Chassis by National Instruments is In Stock & Ready to Ship at Apex Waves. Product Family: 5998-01-550-9004, 5998015509004. 9393. Be the first towrite a review. The SCXI-1308 has thirty-two 249 Ω precision resistors to convert current to voltage when measuring 0–20 mA and 4–20 mA process current sources. com • ni. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. 884. Trusted Supplier for Industrial & Military. Replace x with the corresponding chassis number and y with the corresponding module number. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 00 Add to cart; National Instruments SCXI-1000 4-Slot, AC Chassis for SCXI $ 45. SCXI-1301 National Instruments, NI, SCXI-1301 National Instruments Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United StatesFind many great new & used options and get the best deals for National Instruments NI SCXI-1303 182487B-01 32-Ch. Price and specification data for the based on data from the world's largest marketplace for used machinery. The following sections describe the SCXI-1300/1301 terminal blocks and. Email: info@artisantg. This SCXI-1303. Broken_Arrow. National Instruments SCXI-1129 Frequently Asked Questions . Basically, I will be putting in a relay to detect when there is power to the heating element. Page 2 Sweden 08 587 895 00, Switzerland. For a complete description of. . Every channel has a configurable lowpass filter of 4. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. The NI SCXI-13xx front-mount terminal blocks provide direct The National Instruments SCXI-1102 and SCXI-1112 are designed for high-accuracy thermocouple measurements. View and Download National Instruments SCXI-1000 quick start manual online. The SCXI‑1193 module is designed to integrate with high-frequency instr. The SCXI 1322 (Part Number: 777687-22) is designed to be used with the SCXI-1122 module. NATIONAL INSTRUMENTS NI-SCXI-1327. National Instruments SCC-68 (68-Pin Terminal Block with SCC Expansion Slots) - Starting Price: $79. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。SCXI USB modules are plug-and-play, integrated signal conditioning modules that communicate between an SCXI system and a USB-compatible computer or USB hub, so no intermediate DAQ device is needed. SCXI-1306. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions,Find the National Instruments SCXI-1317 at our website: Click HERE. 9393. SCXI-1303. I removed the bias resistor networks (10 Ω) from the SCXI-1303 (the pullup resistor networks are still there, 10M Ω). Worldwide Technical Support and Product Information ni. I have recently upgraded from Labview 6. SCXI-1129. are not included with this. Worldwide Technical Support and Product Information National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100LOWEST PRICE* National Instruments NI SCXI-1000 4-Slot Chassis Up for sale is a National Instruments 4-slot chassis. and had no problems. Part Number: 776575-57, 185006A-01, 185006B-01. SCXI-1349 National Instruments SCXI-1349 Adapter Board from National Instruments | Buy Today from Artisan. Here is some information from the SCXI-1303 Installation Guide and Specifications. Description: 32 Channel Temperature Data Collection Utilizing Thermocouples Price: Inquire Ref# 36668ke. Fax: (240) 376-1381. The SCXI-1303 also includes circuitry for open-thermocouple detection as well as automatic ground referencing for floating (nongrounded) thermocouples. National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. Find many great new & used options and get the best deals for National Instruments Ni Scxi-1000 4-slot Chassis 181445l - 01 at the best online prices at eBay! Free shipping for many products!. SCXI-1303 National Instruments, NI, SCXI-1303 National Instruments Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug. Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. Instruments from Silicon Valley Test & Measurement at used-line. Member Author 09-14-2007 09:06 AM. Fax: (240) 376-1381. It has a sampling rate of 200 kS/s. 5mV; however using the new version of labview and DAQmx the thermocouples are reading 5V. com. Re: scxi-1300/scxi-1303 andrew_JKTA. Part Numbers: 184642B-01, 184642C-01, 184345D-01, 184345E-01, 776572-26. This grounds the negative terminal on the SCXI-1100 instrumentation amplifier through a 100 kΩ resistor, possibly increasing measurement noise and settling time. Start»All Programs»National Instruments»NI-DAQmx after installing NI-DAQmx. We have New & Used SCXI-1303 32-Channel Isothermal Terminal Block by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. . The SCXI-1303 has pullup and bias resistors that saturate the channel by applying +5 V at the input of the open channel. This model comes with a 10 kHz cut-off frequency filter. Part Number: 187254A-01. This unit uses a DIP switch for chassis addressing. Hi, I have a SCXI-1303, on an SCXI-1102C on an SCXI 1000 chassis. The SCXI-1303 terminal block is for use with the SCXI-1100 and SCXI-1102/B/C modules. com 327 SCXITerminal Blocks Data Acquisition andSCXI-1303: Make: National Instruments: SKU: DP-NATI-SCXI1303-13747288: Price: Request Quote for Price: Lead Time: Request Quote for Lead Time: Related Products.